Change Language :
What is valid for all these points: the closer I know my application and the mentioned parameters, the more specific a material selection and a service life calculation can be. Choosing the right material is crucial for a long service life.

X = load [MPa]
Y = wear [μm/km]
Wear of iglidur plain bearings at low loads, shaft: Cf53, v = 0.1m/s
As the wear of components depends on many different factors, it is difficult to make general statements about the wear behaviour. In a wide range of experiments and tests, measuring wear is the main focus. In testing, it has become clear what deviations are possible between different material pairings. At given loads and surface speeds, wear resistance between common material pairings can still vary slightly by a factor of 10.

X = load [MPa]
Y = wear [μm/km]
Wear of iglidur® plain bearings at medium and high loads, shaft: Cf53, v = 0.1 m/s
Different loads greatly influence the bearing wear. Among the iglidur plain bearings, certain materials are optimised for low loads while others are suitable for use with high or extremely high loads. With its hardened, ground shafts, iglidur J can be described as the most wear-resistant bearing material for light loads. iglidur Q, in contrast, is the specialist for extremely high loads.
Have you not found the required material? There is extensive data on all materials and data sheets in our online shop.
| Material | Temp. [°C] |
|---|---|
| iglidur G | +120 |
| iglidur J | +70 |
| iglidur M250 | +80 |
| iglidur W300 | +120 |
| iglidur X | +210 |
| iglidur K | +90 |
| iglidur P | +100 |
| iglidur GLW | +100 |
| iglidur J260 | +80 |
| iglidur J3 | +70 |
| iglidur J350 | +140 |
| iglidur L250 | +120 |
| iglidur R | +70 |
| iglidur V400 | +130 |
| iglidur X6 | +210 |
| iglidur Z | +200 |
| iglidur® UW500 | +190 |
| iglidur H | +120 |
| iglidur H1 | +170 |
| iglidur H370 | +150 |
| iglidur H2 | +120 |
| iglidur A180 | +70 |
| iglidur A200 | +80 |
| iglidur A351 | +120 |
| iglidur A500 | +190 |
| iglidur A290 | +120 |
| iglidur F | +130 |
| iglidur H4 | +120 |
| iglidur Q | +80 |
| iglidur UW | +70 |
Bearing wear means the erosion of the sliding surface material, i.e. usually in the bearing's inner diameter. The clearance between bearing and shaft results arithmetically from the tolerances of bearing and shaft. The real starting clearance at commissioning is the difference between the measured actual inner diameter of the bearing and the measured actual outer diameter of the shaft. A wear on the inner diameter of the bearing leads to an increase in diameter and thus to an enlargement of the clearance.
Since iglidur plain bearings have no layered structure and thus the entire wall thickness acts as a wear zone, there is no specified wear limit for the bearing. The wear limit is instead determined by the maximum clearance allowed in an application. This can vary significantly depending on the application and user request. Precision control valves allow only a few hundredths of wear (and thus clearance enlargement). In agricultural applications with shaft diameters of over 50mm, a clearance of significantly more than 1mm is often not critical.